Automatic ceiling Fire Sprinkler at the Office Maintaining a working fire sprinkler is requisite for any business

How To Check Your Sprinkler System

Fire sprinkler systems are critical to keeping your employees safe and slowing destruction from out-of-control blazes. Before an inferno takes hold in your office, check that everything is functioning properly through the use of a water pressure gauge.

Sprinkler System Failures
Your fire suppression system may be faulty for any number of reasons, including:

  • Improper valve installation
  • Extensive building construction
  • Alterations to the water distribution system
  • Component damage

Whatever the cause for improper operation, lacking adequate water protection with your building afire is a nightmare scenario nobody should endure. An easy fire sprinkler cleanup in Waleska, GA, remains far preferable to needing a commercial fire and smoke restoration service to rehabilitate extensive destruction.

Sprinkler System Gauge Selection
There are two types of gauges with which you can test your fire sprinkler. Dry gauges are the most common and employ a spring-loaded mechanism to operate. Liquid gauges incorporate glycerin to deliver measurements that are more precise.
Older gauges occasionally contain flaws such as fluttering pointers or leaks. Ones suffering from these or any other imperfections must be discarded and new ones purchased. Check that whichever version you choose has Underwriters Laboratory and Factory Mutual approvals, both of which are required by the National Fire Protection Association. These quality seals provide assurance that yours will deliver accurate readouts.
Manufacturers commonly bundle the necessary plug, nipple and 3-way valve along with these devices. If yours lacks the required installation components, consult a professional to be sure you are acquiring ones that reflect the correct measurements. Once in place, the 3.5-inch dial measures both water and air pressure. Research your manual to determine the optimum gauge numbers. If yours falls outside of the acceptable range, promptly hire a repair specialist.
Maintaining a working fire sprinkler is requisite for any business. See that yours is operating properly by selecting and attaching the best gauge for your network and then viewing it regularly.